{"id":2267,"date":"2025-12-10T17:13:04","date_gmt":"2025-12-10T09:13:04","guid":{"rendered":"https:\/\/www.luckywwtp.com\/?p=2267"},"modified":"2025-12-10T17:13:04","modified_gmt":"2025-12-10T09:13:04","slug":"what-are-the-chemical-treatment-methods-for-pharmaceutical-wastewater","status":"publish","type":"post","link":"https:\/\/www.luckywwtp.com\/es\/what-are-the-chemical-treatment-methods-for-pharmaceutical-wastewater\/","title":{"rendered":"\u00bfCu\u00e1les son los m\u00e9todos de tratamiento qu\u00edmico de las aguas residuales farmac\u00e9uticas?"},"content":{"rendered":"<p><\/p>\n\n\n\n<p>Cuando se aplican m\u00e9todos qu\u00edmicos, el uso excesivo de determinados reactivos puede provocar f\u00e1cilmente una contaminaci\u00f3n secundaria de las masas de agua. Por lo tanto, antes de dise\u00f1ar el tratamiento deben realizarse las investigaciones experimentales pertinentes. Los m\u00e9todos qu\u00edmicos incluyen el m\u00e9todo de hierro-carbono, el m\u00e9todo de oxidaci\u00f3n-reducci\u00f3n qu\u00edmica (reactivo de Fenton, H2O2, O3) y la tecnolog\u00eda de oxidaci\u00f3n profunda.<\/p>\n\n\n\n<p>(1) M\u00e9todo de oxidaci\u00f3n Este m\u00e9todo puede mejorar la biodegradabilidad de las aguas residuales y tambi\u00e9n tiene una buena tasa de eliminaci\u00f3n de DQO.<\/p>\n\n\n\n<p>El tratamiento por oxidaci\u00f3n con ox\u00edgeno de tres tipos de aguas residuales de antibi\u00f3ticos mostr\u00f3 que las aguas residuales tratadas con oxidaci\u00f3n con ozono no s\u00f3lo mejoraban la relaci\u00f3n DBO5\/DQO, sino que tambi\u00e9n alcanzaban una tasa de eliminaci\u00f3n de DQO superior a 80%.<\/p>\n\n\n\n<p>M\u00e9todo de tratamiento con reactivo de Fenton La combinaci\u00f3n de sal ferrosa y H2O2 se denomina reactivo de Fenton, que puede eliminar eficazmente la materia org\u00e1nica recalcitrante que las tecnolog\u00edas tradicionales de tratamiento de aguas residuales no pueden eliminar. Con investigaciones posteriores, se han introducido la luz ultravioleta (UV) y el oxalato (C2O42-) en el reactivo de Fenton, lo que ha mejorado enormemente su capacidad de oxidaci\u00f3n. Utilizando TiO2 como catalizador y una l\u00e1mpara de mercurio de baja presi\u00f3n de 9W como fuente de luz, se utiliz\u00f3 el reactivo de Fenton para tratar aguas residuales farmac\u00e9uticas, consiguiendo una tasa de decoloraci\u00f3n de 98% y una tasa de eliminaci\u00f3n de DQO de 93,5%, con una disminuci\u00f3n de los compuestos de nitrobenceno de 8,15 mg\/L a 0,43 mg\/L.<\/p>\n\n\n\n<p>(2) M\u00e9todo del hierro-carbono El funcionamiento industrial demuestra que el uso del Fe-C como paso previo al tratamiento de las aguas residuales farmac\u00e9uticas mejora significativamente la biodegradabilidad del efluente. Se utiliz\u00f3 un proceso combinado de hierro-carb\u00f3n-microelectrolisis-flotaci\u00f3n anaer\u00f3bica-aer\u00f3bica-a\u00e9rea para tratar las aguas residuales procedentes de la producci\u00f3n de productos farmac\u00e9uticos intermedios como el metacrilato de metilo y el clorhidrato de ciclofloxacino. Tras el tratamiento mediante el m\u00e9todo de hierro-carbono, la tasa de eliminaci\u00f3n de DQO alcanz\u00f3 25%, y el efluente final cumpli\u00f3 las normas de vertido de aguas residuales integrales.<\/p>","protected":false},"excerpt":{"rendered":"<p>When applying chemical methods, excessive use of certain reagents can easily lead to secondary pollution of water bodies. Therefore, relevant experimental research should be conducted before designing the treatment. Chemical methods include the iron-carbon method, chemical oxidation-reduction method (Fenton&#8217;s reagent, H2O2, O3), and deep oxidation technology. (1) Oxidation Method This method can improve the biodegradability&#8230;<\/p>","protected":false},"author":1,"featured_media":2002,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","footnotes":""},"categories":[1,32],"tags":[736,738,737],"class_list":["post-2267","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-categorized","category-waste-water-treatment-news","tag-chemical-treatment-watstewater","tag-fenton-treatment","tag-oxidation-method-treatment"],"_links":{"self":[{"href":"https:\/\/www.luckywwtp.com\/es\/wp-json\/wp\/v2\/posts\/2267","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.luckywwtp.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.luckywwtp.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.luckywwtp.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.luckywwtp.com\/es\/wp-json\/wp\/v2\/comments?post=2267"}],"version-history":[{"count":1,"href":"https:\/\/www.luckywwtp.com\/es\/wp-json\/wp\/v2\/posts\/2267\/revisions"}],"predecessor-version":[{"id":2268,"href":"https:\/\/www.luckywwtp.com\/es\/wp-json\/wp\/v2\/posts\/2267\/revisions\/2268"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.luckywwtp.com\/es\/wp-json\/wp\/v2\/media\/2002"}],"wp:attachment":[{"href":"https:\/\/www.luckywwtp.com\/es\/wp-json\/wp\/v2\/media?parent=2267"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.luckywwtp.com\/es\/wp-json\/wp\/v2\/categories?post=2267"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.luckywwtp.com\/es\/wp-json\/wp\/v2\/tags?post=2267"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}